LISTINGS AND CODE APPROVALS
THE BUILDERS BOX SERIES HAS BEEN TESTED AND APPROVED IN ACCORDANCE WITH THE
CSA, No.220391, STANDARDS FOR FIXED AND LOCATION
DEDICATED ELECTRIC ROOM HEATERS.
MODEL SPECIFICATIONS
!!! WARNING !!!
THE INSTALLATION OF THE FIREPLACE UNIT MUST COMPLY WITH THE APPLICABLE
LOCAL AND/ OR NATIONAL ELECTRICAL CODES AND UTILITY REQUIREMENTS.
THIS INSTALLATION SHOULD BE ENTRUSTED TO DULY QUALIFIED
PERSONNEL WHERE REQUIRED BY LAW.
!POWER SELECTION WARNING!
This unit is factory wired for 120 volt power supply.
If 120 volt operation is required, slide the voltage switch
and reconfigure the wiring accordingly (see figure 2).
Wires L1, L2, N & G are attached to the rear of
the junction box for easy access.
! !
1) Rough in framing following the
recommended dimensions. (see figure 1)
2) Allow at least 8” of service cable for
connecting power supply wire to junction
box on fireplace insert when installing
before finishing wall. Allow up to 4 feet of
service cable for connecting power supply
wire to junction box on fireplace insert
after finishing wall.
3) Remove the outer jacket and strip the
individual conductors ½” from end.
4) Loosen the screw securing the junction
box cover and remove the cover.
5) Place unit in position in the framed
opening, level with shims if necessary
and attach unit to frame using mounting
flanges provided ( see Section 3).
6) Wire a dedicated, properly fused circuit with
a 15 amp rating for the appropriate voltage
(120, 208/240). (See table above)
7) Place all connections inside the junction
box. Secure the junction box cover on the
unit.
When installing a cable clamp make sure it
grips only the jacket of the service cable
and thermostat wire.
STEP - BY - STEP INSTALLATION OVERVIEW
(please read all instructions before installation)
E-2
Model Number Description Voltage Watts Amps
39EB500ARA 39”Electric Box without any doors 120/208/240 1440/2100/2800 YES 12/10.1/11.7
Remote
Control
39EB500GRA 39”Electric Box with glass front 120/208/240 1440/2100/2800 YES 12/10.1/11.7
39EB500GRS 39”Electric Box with double swing door 120/208/240 1440/2100/2800 YES 12/10.1/11.7